Type of steam turbine | 4MW high-efficiency Condensing Steam Turbine generator | |
Model No. of steam turbine | N4-0.88 | |
Rated power | MW | 4 |
Rated speed | r/min | 3000 |
Rated steam inlet pressure | Mpa | 0.88 |
Rated steam inlet temperature | ºC | 280 |
Rated steam inlet flow | t/h | 26 |
Rated exhaust steam pressure | Mpa | 0.008 |
Rated steam consumption | kg/kw.h | 6.5 |
Max component weight | ton | ~9 |
Dimension | meter | 4.5*3.6*2.7 |
OEM service is available. According to customers's parameter requirement, we can customized R&D,produce and supply steam turbines |
Other models of condensing steam turbines
Model | Power (MW) |
Steam inlet parameter | Steam consumption (kg/kw.h) |
Steam intake (t/h) |
Speed (r/min) |
exhaust pressure (Mpa) |
|
Pressure (Mpa) |
Temperature (ºC) |
||||||
N1.2-0.155 | 1.2 | 0.155 | 195 | 9.76 | 11.71 | 3000 | 0.007 |
N4-0.88 | 4 | 0.88 | 280 | 6.5 | 26 | 3000 | 0.008 |
N6-3.43 | 6 | 3.43 | 435 | 4.6 | 27.6 | 3000 | 0.0076 |
N15-4.9 | 15 | 4.9 | 470 | 3.95 | 59.25 | 3000 | 0.007 |
N25-8.83 | 25 | 8.83 | 535 | 3.58 | 89.5 | 6500/3000 | 0.006 |
N15-3.43 | 15 | 4.9 | 470 | 4.1 | 61.5 | 3000 | 0.007 |
dynamo | Exciter | |||||
model |
capacity | Voltage | Power Factor | efficiency | power | Voltage |
KVA | V | % | KW | V | ||
QFK-3-2 | 3750 | 6300 3150 |
0.8 | 95.3 | 30 | 100 |
QF-3-2 | 3750 | 10500 6300 |
0.8 | 95.3 | 30 | 100 |
QF-6-2 | 7500 | 10500 6300 |
0.8 | 96.4 | 45 | 150 |
QF-7-2 | 8750 | 10500 6300 |
0.8 | 97 | 45 | 150 |
QF-12-2 | 15000 | 10500 6300 |
0.8 | 97 | 65 | 230 |
QF-15-2 | 18750 | 10500 6300 |
0.8 | 97 | 65 | 230 |
QF-25-2 | 31250 | 10500 6300 |
0.8 | 97.4 | 105 | 230 |
QF-30-2 | 37500 | 10500 6300 |
0.8 | 97.6 | 105 | 230 |
Our company custom-designs and independently develops high-efficiency condensing steam turbine units, which are multi-stage small enthalpy drop impulse steam turbines. Different from the condensing steam turbine rotors of other manufacturers, the design has 2-4 more pressure stages; the design reduces the distance between flow stages, allowing more stages to be arranged in the flow part. The enthalpy drop of each stage is reduced, the flow diameter is decreased, and the blade height loss is significantly reduced. The flow part of the condensing steam turbine also optimizes the profile design of blades, nozzles, and diaphragm nozzles, effectively reducing all losses in the flow part of the condensing steam turbine, thereby improving the mechanical conversion efficiency of the condensing steam turbine and having a wide load adaptation capacity and overload capacity. This technology was selected into the 2019 China Industrial Energy Conservation Technology and Equipment Recommendation Catalog and Cases issued by the Ministry of Industry and Information Technology of China.
Our company's main technical configuration is to optimize the blade profile of conventional units. Through thermal calculation and following the law of "conservation of energy", the design condition parameters of the original unit are matched and optimized with the actual operating conditions. Meanwhile, new partitions are matched. The purpose is to revise the flow area and improve the flow structure, so that the unit can do work effectively and smoothly, thereby achieving the goal of energy saving and efficiency improvement.
The high-efficiency labyrinth teeth steam seals independently designed by our company have the following characteristics:
Product Service Life
All components of the condensing steam turbine adopt high-specification configurations to ensure safe operation of the unit. The designed service life of major components is not less than 30 years.
Excellent Hardware Processing Support and Testing Capabilities
With modern production workshops, dozens of sets of advanced hardware processing equipment, and a complete range of testing equipment, we can guarantee the processing accuracy of various components. All products undergo strict testing and inspection before leaving the factory, and corresponding reports are issued.
1. Q: How to determine the parameters of steam turbine?
R: Design steam turbine units with different working conditions according to the customer's current production technical parameters to meet production needs.
2. Q: How to determine the quality of steam turbine?
R: You can do it through on-site field visits and provide relevant inspection and testing reports and other materials.
3. Q:How to install the steam turbine?
R: After the steam turbine arrive at your site, we will dispatch relevant technical personnel to your country for on-site installation and debugging.
4. Q: How to ensure after-sales service?
R: The company's technical staff solves difficult problems online and offline. If needed, our company can our company can dispatch relevant technical personnels to your country for on-site installation and maintenance.