Steam Turbine Replacement for Desuperheating and Pressure Reduction Device Power Generation Project

Product Details
Customization: Available
After-sales Service: Global Service
Warranty: 12 Months After Supply
Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (20)
  • Steam Turbine Replacement for Desuperheating and Pressure Reduction Device Power Generation Project
  • Steam Turbine Replacement for Desuperheating and Pressure Reduction Device Power Generation Project
  • Steam Turbine Replacement for Desuperheating and Pressure Reduction Device Power Generation Project
  • Steam Turbine Replacement for Desuperheating and Pressure Reduction Device Power Generation Project
  • Steam Turbine Replacement for Desuperheating and Pressure Reduction Device Power Generation Project
  • Steam Turbine Replacement for Desuperheating and Pressure Reduction Device Power Generation Project
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • FAQ
Overview

Basic Info.

Model NO.
1MW~60MW
Power
1MW~60MW
Generator Type
Synchronous Generator
Certification
CCC, ISO, TLC, CE
Standard
Nonstandard
Form
Impulsiv
Material
Comply with Standards
Medium
Steam
Adjustment Method
Electro-Hydraulic Regulation
Transport Package
Sea and Land Transport
Specification
Different specifications
Trademark
Anhuizhengyufeng
Origin
Anhuiwuhu
Production Capacity
100

Product Description

Product Description

1. In the production process of high-energy-consuming industrial enterprises, a considerable amount of waste heat and pressure is wasted; it is mainly divided into heat sources and calorific value waste in kilns, ore-fired furnaces, reactors, temperature and pressure reduction devices and other production processes, collectively referred to as waste heat and pressure resource waste.
2. Our company can equip different energy-saving technology transformation plans according to the different actual waste heat and pressure waste of the owner, equip waste heat boilers to convert calorific value to produce steam, and then equip condensing or back-pressure steam turbine units to generate electricity or drive equipment, directly generating economic benefits. The power generation project is built as a self-provided power station within the owner's enterprise, and all the electricity generated is used for the owner's production or lighting.
3. Product life: The design service life of the main parts is not less than 30 years.

 

Detailed Photos

Steam Turbine Replacement for Desuperheating and Pressure Reduction Device Power Generation ProjectSteam Turbine Replacement for Desuperheating and Pressure Reduction Device Power Generation ProjectSteam Turbine Replacement for Desuperheating and Pressure Reduction Device Power Generation ProjectSteam Turbine Replacement for Desuperheating and Pressure Reduction Device Power Generation ProjectSteam Turbine Replacement for Desuperheating and Pressure Reduction Device Power Generation ProjectSteam Turbine Replacement for Desuperheating and Pressure Reduction Device Power Generation Project

Product Parameters

Steam turbine parameters

model Power(MW) Steam inlet parameters Steam consumption(kg/kw.h) Steam intake(t/h) Speed(r/min)
    Pressure(Mpa) Temperature(ºC)      
B1.5-2.35/0.49 1.5 2.35 390 13.33 20 6500/3000
B3-3.43/0.49 3 3.43 435 938 29.4 6500/3000
B3-4.9/3.1 3 4.9 470 37.7 113.1 3000
B4.5-8.83/2.2 4.5 8.83 535 12.2 54.9 6500/3000
B6-0.98/0.245 6 0.981 280 16.0 96.0 3000
B6-4.9/0.981 6 4.9 470 11.1 66.6 3000
B7-4.9/0.7 7 4.9 470 9.55 66.9 3000
B7-8.83/3.63 7 8.83 535 18.57 130 3000
B9-4.9/0.49 9 4.9 470 7.90 71.1 3000
B12-4.9/1.27 12 4.9 470 12.08 145 3000
B15-4.9/0.98 15 4.9 470 10.30 154.5 3000
B25-4.9/0.98 25 4.9 470 10.25 256.3 3000
B30-4.9/0.98 30 4.9 470 10.18 305.4 3000
B10-13.1/6.9 10 13.1 535 24.6 240 3000

Generator parameters
dynamo Exciter
model capacity Voltage Power Factor efficiency power Voltage
  KVA V   % KW V
QFK-3-2 3750 6300
3150
0.8 95.3 30 100
QF-3-2 3750 10500
6300
0.8 95.3 30 100
QF-6-2 7500 10500
6300
0.8 96.4 45 150
QF-7-2 8750 10500
6300
0.8 97 45 150
QF-12-2 15000 10500
6300
0.8 97 65 230
QF-15-2 18750 10500
6300
0.8 97 65 230
QF-25-2 31250 10500
6300
0.8 97.4 105 230
QF-30-2 37500 10500
6300
0.8 97.6 105 230
 

FAQ

1. Question: How to determine product parameters?
Reply: Design steam turbine units with different working conditions according to the customer's current production technical parameters to meet production needs.
2. Question: How to determine product quality?
Reply: You can do it through on-site field visits and provide relevant inspection and testing reports and other materials.
3. Question: How to ensure after-sales service?
Reply: The company's technical staff solves difficult problems online and offline.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier