Model | Power (MW) |
Steam inlet parameters | Steam Consumption (kg/kw.h) |
Steam Intake (t/h) |
Speed (r/min) |
|
Pressure (Mpa) |
Temperature (ºC) |
|||||
B1.5-3.43/0.981 | 1.5 | 3.43 | 435 | 14.2 | 21.3 | 6500/3000 |
B3-3.43/0.49 | 3 | 3.43 | 435 | 938 | 29.4 | 6500/3000 |
B4.5-8.83/2.2 | 4.5 | 8.83 | 535 | 12.2 | 54.9 | 6500/3000 |
B6-0.98/0.245 | 6 | 0.981 | 280 | 16.0 | 96.0 | 3000 |
B7-4.9/0.7 | 7 | 4.9 | 470 | 9.55 | 66.9 | 3000 |
B7.5-3.43/0.49 | 7.5 | 3.43 | 435 | 9.6 | 72 | 3000 |
B7-8.83/3.63 | 7 | 8.83 | 535 | 18.28 | 128 | 6500/3000 |
B9-4.9/0.49 | 9 | 4.9 | 470 | 7.90 | 71.1 | 3000 |
B12-4.9/1.27 | 12 | 4.9 | 470 | 12.08 | 145 | 3000 |
B15-4.9/0.98 | 15 | 4.9 | 470 | 10.30 | 154.5 | 3000 |
B25-4.9/0.98 | 25 | 4.9 | 470 | 10.25 | 256.3 | 3000 |
B30-4.9/0.98 | 30 | 4.9 | 470 | 10.18 | 305.4 | 3000 |
B22-9.0/0.98 | 22 | 9.0 | 535 | 7.25 | 159.5 | 3000 |
B20-8.83/4.1 | 20 | 8.83 | 535 | 19.1 | 382 | 3000 |
B32-12.7/0.98 | 32 | 12.7 | 535 | 7.13 | 228.16 | 3000 |
Model | Power(MW) | Steam Inlet Parameters | Steam Consumption (kg/kw.h) |
Steam Intake (t/h) |
Speed (r/min) |
Exhaust Pressure (Mpa) |
|
Pressure (Mpa) |
Temperature (ºC) |
||||||
N1.2-0.155 | 1.2 | 0.155 | 195 | 9.76 | 11.71 | 3000 | 0.007 |
N4-0.88 | 4 | 0.88 | 280 | 6.5 | 26 | 3000 | 0.008 |
N6-3.43 | 6 | 3.43 | 435 | 4.6 | 27.6 | 3000 | 0.0076 |
N15-4.9 | 15 | 4.9 | 470 | 3.95 | 59.25 | 3000 | 0.007 |
N25-8.83 | 25 | 8.83 | 535 | 3.58 | 89.5 | 6500/3000 | 0.006 |
N15-3.43 | 15 | 4.9 | 470 | 4.1 | 61.5 | 3000 | 0.007 |
Model | Power (MW) |
Steam Inlet Parameters | Pumping Parameters | Steam Consumption (kg/kw.h) |
Speed (r/min) |
Exhaust Pressure (Mpa) |
|||
Pressure (Mpa) |
Temperature (ºC) |
Flow (t/h) |
Pressure (Mpa) |
Flow (t/h) |
|||||
CB15-3.43/0.98/0.53 | 15 | 3.43 | 435 | 150.2 | 0.98 | 20 | 10 | 3000 | 0.53 |
CB14.1-4.9/3.0/0.9 | 14.1 | 4.9 | 470 | 150 | 3 | 12 | 10.638 | 3000 | 0.9 |
CB13.6-4.9/2.5/0.98 | 13.6 | 4.9 | 470 | 152.6 | 2.5 | 12 | 11.22 | 3000 | 0.98 |
CB10-8.83/0.98/0.6 | 10 | 8.83 | 535 | 75 | 0.98 | 25 | 7.5 | 3000 | 0.6 |
CB25-8.83/2.8/0.98 | 25 | 8.83 | 535 | 219 | 2.8 | 70 | 8.76 | 3000 | 0.98 |
CB30-9.2/3.0/0.8 | 30 | 9.2 | 535 | 239.5 | 3 | 60 | 7.98 | 3000 | 0.8 |
CB18-9.2/2.8/0.98 | 18 | 9.2 | 535 | 160.2 | 2.8 | 40 | 8.9 | 3000 | 0.98 |
CB16-12.7/2.5/1.76 | 16 | 12.7 | 535 | 152 | 2.5 | 35 | 9.5 | 3000 | 1.76 |
Model | Power (MW) |
Steam Inlet Parameters | Pumping Parameters | Steam Consumption (kg/kw.h) |
Speed (r/min) |
Exhaust Pressure (Mpa) |
|||
Pressure (Mpa) |
Temperature (ºC) |
Flow (t/h) |
Pressure (Mpa) |
Flow (t/h) |
|||||
C15-3.43/0.98 | 15 | 3.43 | 435 | 101.5 | 0.98 | 45 | 6.76 | 3000 | 0.007 |
C12-6.5/1.2 | 12 | 6.5 | 470 | 105.3 | 1.2 | 75 | 7.02 | 3000 | 0.007 |
C20-8.83/0.98 | 20 | 8.83 | 535 | 90 | 0.98 | 45 | 6 | 3000 | 0.007 |
C25-3.43/0.98 | 25 | 3.43 | 435 | 101.5 | 0.98 | 45 | 6.76 | 3000 | 0.007 |
C30-3.43/0.98 | 30 | 3.43 | 435 | 101.5 | 0.98 | 45 | 6.76 | 3000 | 0.007 |
C55-8.83/0.98 | 55 | 8.83 | 535 | 90 | 0.98 | 45 | 6 | 3000 | 0.007 |
C60-8.83/0.98 | 60 | 8.83 | 535 | 90 | 0.98 | 45 | 6 | 3000 | 0.007 |
DYNAMO | EXCITER | |||||
Model | Capacity | Voltage | Power Factor | Efficiency | Power | Voltage |
KVA | V | % | kW | V | ||
QFK-3-2 | 3750 | 6300 | 0.8 | 95.3 | 30 | 100 |
3150 | ||||||
QF-3-2 | 3750 | 10500 | 0.8 | 95.3 | 30 | 100 |
6300 | ||||||
QF-6-2 | 7500 | 10500 | 0.8 | 96.4 | 45 | 150 |
6300 | ||||||
QF-7-2 | 8750 | 10500 | 0.8 | 97 | 45 | 150 |
6300 | ||||||
QF-12-2 | 15000 | 10500 | 0.8 | 97 | 65 | 230 |
6300 | ||||||
QF-15-2 | 18750 | 10500 | 0.8 | 97 | 65 | 230 |
6300 | ||||||
QF-25-2 | 31250 | 10500 | 0.8 | 97.4 | 105 | 230 |
6300 | ||||||
QF-30-2 | 37500 | 10500 | 0.8 | 97.6 | 105 | 230 |
6300 |
Steam Turbine is a kind of rotating power machinery that converts the thermal energy of steam into mechanical energy, and is widely used in the field of thermal power generation.
Working Principle
The steam turbine is based on the thermodynamic cycle, and the blades are rotated through high-temperature and high-pressure steam to do work. The steam generated by the boiler enters the steam turbine, expands and accelerates in the nozzle or static blade, the heat energy is converted into kinetic energy, the high-speed steam hits the moving blades (rotor blades), pushes the rotor to rotate, the kinetic energy is converted into mechanical energy, and the steam turbine rotor connection drives the generator rotor to rotate for power generation output.
Combined Heat and Power:
Combined heat and power (CHP) uses the waste heat generated by the fuel in the power generation process, which is converted into a useful heat supply through a heat recovery device, while also generating electricity. This technology can meet the needs of heating and power supply at the same time, improving the efficiency and economy of energy use.
Generator generation: The boiler steam is used to generate electricity first, and the remaining steam heat energy is then put into a certain industrial process, and the electricity generated at the same time is also put into the industrial process, and the remaining electricity is sold to the power grid. Industries suitable for medium-temperature processes: food, paper, chemicals, farming, agriculture.
Post-power generation: The boiler steam is first used in an industrial process, and the remaining steam heat energy is then put into power generation, and the electricity generated at the same time is also put into the industrial process, and the surplus electricity is sold to the power grid.
1. Q: How to determine the parameters of the steam turbine and get custom service?
A: Our technical team will help to find a suitable steam turbine solution according to your current technical requirements and energy-saving target. Customized equipment will be manufactured and tested in our factory before shipment.
2. Q: Will installation services be provided?
A: Yes. We will dispatch our technical team to your site for installation and debugging upon equipment arrival.
3. Q: Can I expect to easily access after-sales support when needed?
A: Rest assured. Our technical team provides dual-channel support(online/onsite) to resolve all potential issues. When necessary, we will promptly dispatch engineers to your site for installation and maintenance.
4. Q: Does your company welcome on-site visits?
A: Yes. We warmly welcome scheduled facility visits and will arrange every details for our meeting.
5. Q: Do you offer second-hand equipment?
A: Yes. You may browse our second-hand equipment category in the product section. Inquiries for technical details are welcome.
6. Q: Packaging Specifications
A: Seaworthy package. Standard packaging uses stretch film. Also provide custom wooden cases for specialized equipment or upon request.