Customization: | Available |
---|---|
After-sales Service: | Global Service |
Warranty: | 12 Months After Supply |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. In the production process of high-energy-consuming industrial enterprises, a considerable amount of waste heat and pressure is wasted; it is mainly divided into heat sources and calorific value waste in kilns, ore-fired furnaces, reactors, temperature and pressure reduction devices and other production processes, collectively referred to as waste heat and pressure resource waste.
2. Our company can equip different energy-saving technology transformation plans according to the different actual waste heat and pressure waste of the owner, equip waste heat boilers to convert calorific value to produce steam, and then equip condensing or back-pressure steam turbine units to generate electricity or drive equipment, directly generating economic benefits. The power generation project is built as a self-provided power station within the owner's enterprise, and all the electricity generated is used for the owner's production or lighting.
3. Product life: The design service life of the main parts is not less than 30 years.
Steam turbine parameters
model | Power(MW) | Steam inlet parameters | Steam consumption(kg/kw.h) | Steam intake(t/h) | Speed(r/min) | |
Pressure(Mpa) | Temperature(ºC) | |||||
B1.5-2.35/0.49 | 1.5 | 2.35 | 390 | 13.33 | 20 | 6500/3000 |
B3-3.43/0.49 | 3 | 3.43 | 435 | 938 | 29.4 | 6500/3000 |
B3-4.9/3.1 | 3 | 4.9 | 470 | 37.7 | 113.1 | 3000 |
B4.5-8.83/2.2 | 4.5 | 8.83 | 535 | 12.2 | 54.9 | 6500/3000 |
B6-0.98/0.245 | 6 | 0.981 | 280 | 16.0 | 96.0 | 3000 |
B6-4.9/0.981 | 6 | 4.9 | 470 | 11.1 | 66.6 | 3000 |
B7-4.9/0.7 | 7 | 4.9 | 470 | 9.55 | 66.9 | 3000 |
B7-8.83/3.63 | 7 | 8.83 | 535 | 18.57 | 130 | 3000 |
B9-4.9/0.49 | 9 | 4.9 | 470 | 7.90 | 71.1 | 3000 |
B12-4.9/1.27 | 12 | 4.9 | 470 | 12.08 | 145 | 3000 |
B15-4.9/0.98 | 15 | 4.9 | 470 | 10.30 | 154.5 | 3000 |
B25-4.9/0.98 | 25 | 4.9 | 470 | 10.25 | 256.3 | 3000 |
B30-4.9/0.98 | 30 | 4.9 | 470 | 10.18 | 305.4 | 3000 |
B10-13.1/6.9 | 10 | 13.1 | 535 | 24.6 | 240 | 3000 |
dynamo | Exciter | |||||
model | capacity | Voltage | Power Factor | efficiency | power | Voltage |
KVA | V | % | KW | V | ||
QFK-3-2 | 3750 | 6300 3150 |
0.8 | 95.3 | 30 | 100 |
QF-3-2 | 3750 | 10500 6300 |
0.8 | 95.3 | 30 | 100 |
QF-6-2 | 7500 | 10500 6300 |
0.8 | 96.4 | 45 | 150 |
QF-7-2 | 8750 | 10500 6300 |
0.8 | 97 | 45 | 150 |
QF-12-2 | 15000 | 10500 6300 |
0.8 | 97 | 65 | 230 |
QF-15-2 | 18750 | 10500 6300 |
0.8 | 97 | 65 | 230 |
QF-25-2 | 31250 | 10500 6300 |
0.8 | 97.4 | 105 | 230 |
QF-30-2 | 37500 | 10500 6300 |
0.8 | 97.6 | 105 | 230 |
1. Question: How to determine product parameters?
Reply: Design steam turbine units with different working conditions according to the customer's current production technical parameters to meet production needs.
2. Question: How to determine product quality?
Reply: You can do it through on-site field visits and provide relevant inspection and testing reports and other materials.
3. Question: How to ensure after-sales service?
Reply: The company's technical staff solves difficult problems online and offline.